Date: Tue, 24 Feb 1998 22:06:51 +0100 (MET) From: Johan Gustavsson To: mdvorkin@vertel.com Cc: jmaxwell@POMONA.EDU, analogue@hyperreal.org Subject: Re: Orgon Enigiser, from the archives > FIFTEEN VCFs? That is crazy.. What do you mean by switchable? > Switchable mode (ala BP, LP, HP) or switchable slope (e.g. 12/24db)? Fifteen switchable filter *modes*, not fifteen filters. You may choose between 6, 12, 18 and 24 db/oct LP, 6 db/oct phaser, notch and HP, 6db notch followed by a 6, 12 or 18 db LP at a slightly higher cutoff point, 6 db HP followed by a 6, 12 or 18 db LP in the same way, a steeper phaser (?) and a phaser/BP combo. That should make 15. They're selected with two stepped knobs, one going "A B C" and the other going "1 2 3 4 P", som no VCing the filter type. /Moxie (Digging some more)